Autor/inn/enHou, Lei; Du, Xinli; Boulgouris, Nikolaos V.; Hafeez, Nauman; Coulson, Chris; Irving, Richard; Begg, Philip; Brett, Peter
TitelA Capacitive Cochlear Implant Electrode Array Sensing System to Discriminate Fold-Over Pattern
QuelleIn: Journal of Speech, Language, and Hearing Research, 64 (2021) 9, S.3685-3696 (12 Seiten)
PDF als Volltext Verfügbarkeit 
ZusatzinformationORCID (Hou, Lei)
Spracheenglisch
Dokumenttypgedruckt; online; Zeitschriftenaufsatz
ISSN1092-4388
SchlagwörterDeafness; Hearing Impairments; Assistive Technology; Surgery; Measurement Techniques
AbstractPurpose: During insertion of the cochlear implant electrode array, the tip of the array may fold back on itself and can cause serious complications to patients. This article presents a sensing system for cochlear implantation in a cochlear model. The electrode array fold-over behaviors can be detected by analyzing capacitive information from the array tip. Method: Depending on the angle of the array tip against the cochlear inner wall when it enters the cochlear model, different insertion patterns of the electrode array could occur, including smooth insertion, buckling, and fold-over. The insertion force simulating the haptic feedback for surgeons and bipolar capacitance signals during the insertion progress were collected and compared. The Pearson correlation coefficient (PCC) was applied to the collected capacitive signals to discriminate the fold-over pattern. Results: Forty-six electrode array insertions were conducted and the deviation of the measured insertion force varies between a range of 20% and 30%. The capacitance values from electrode pair (1, 2) were recorded for analyzing. A threshold for the PCC is set to be 0.94 that can successfully discriminate the fold over insertions from the other two types of insertions, with a success rate of 97.83%. Conclusions: Capacitive measurement is an effective method for the detection of faulty insertions and the maximization of the outcome of cochlear implantation. The proposed capacitive sensing system can be used in other tissue implants in vessels, spinal cord, or heart. (As Provided).
AnmerkungenAmerican Speech-Language-Hearing Association. 2200 Research Blvd #250, Rockville, MD 20850. Tel: 301-296-5700; Fax: 301-296-8580; e-mail: slhr@asha.org; Web site: http://jslhr.pubs.asha.org
Erfasst vonERIC (Education Resources Information Center), Washington, DC
Update2024/1/01
Literaturbeschaffung und Bestandsnachweise in Bibliotheken prüfen
 

Standortunabhängige Dienste
Bibliotheken, die die Zeitschrift "Journal of Speech, Language, and Hearing Research" besitzen:
Link zur Zeitschriftendatenbank (ZDB)

Artikellieferdienst der deutschen Bibliotheken (subito):
Übernahme der Daten in das subito-Bestellformular

Tipps zum Auffinden elektronischer Volltexte im Video-Tutorial

Trefferlisten Einstellungen

Permalink als QR-Code

Permalink als QR-Code

Inhalt auf sozialen Plattformen teilen (nur vorhanden, wenn Javascript eingeschaltet ist)

Teile diese Seite: