Suche

Wo soll gesucht werden?
Erweiterte Literatursuche

Ariadne Pfad:

Inhalt

Literaturnachweis - Detailanzeige

 
Autor/inn/enFinn, Kevin J.; Saint-Maurice, Pedro F.; Karsai, István; Ihász, Ferenc; Csányi, Tamás
TitelAgreement between Omron 306 and Biospace InBody 720 Bioelectrical Impedance Analyzers (BIA) in Children and Adolescents
QuelleIn: Research Quarterly for Exercise and Sport, 86 (2015), (8 Seiten)
PDF als Volltext Verfügbarkeit 
Spracheenglisch
Dokumenttypgedruckt; online; Zeitschriftenaufsatz
ISSN0270-1367
SchlagwörterChildren; Adolescents; Preadolescents; Measurement Equipment; Human Body; Validity; Regression (Statistics); Age Differences; Body Composition; Gender Differences; Predictor Variables; Foreign Countries; Physical Fitness; Classification; Measurement Techniques; Hungary
AbstractPurpose: The purpose of this study was to test the convergent validity of Omron 306 using Biospace InBody 720. Method: A total of 267 participants (145 boys; aged 10.4-17.9 years) completed testing during a single session. Each measure provided percent body fat (%BF), while the InBody 720 included fat-free mass (FFM). The validity was examined using the Pearson correlation. Limits of agreement (LOA) and multiple linear regression were also used to determine the impact of both age and FFM on the associations between the 2 measures. Results: The 2 measures of %BF were correlated by 0.63 (p < 0.001) in boys and 0.89 (p < 0.001) in girls. The mean difference (i.e., InBody--Omron) for %BF in boys was -4.7% with a lower LOA of -20.5% and upper LOA of 11.2%. The same comparison for girls resulted in a difference of 3.0% with a lower LOA of -10% and upper LOA of 4%. Examination of the residuals obtained from multiple linear regression indicated that FFM was the only statistically significant predictor of differences in boys (ßFFM = -0.25 ± 0.08%, p = 0.001). There were no significant associations for girls. Conclusions: Findings indicate that estimates of %BF obtained from Omron in boys exceed estimates from InBody 720. Disagreement was evident in younger boys with lower levels of FFM. Girls' %BF was closer between the 2 bioelectrical impedance analyzer measures (less residual) with age and FFM not explaining the disagreement. Overall, the 2 measures were not equivalent. (As Provided).
AnmerkungenRoutledge. Available from: Taylor & Francis, Ltd. 325 Chestnut Street Suite 800, Philadelphia, PA 19106. Tel: 800-354-1420; Fax: 215-625-2940; Web site: http://www.tandf.co.uk/journals
Erfasst vonERIC (Education Resources Information Center), Washington, DC
Update2020/1/01
Literaturbeschaffung und Bestandsnachweise in Bibliotheken prüfen
 

Standortunabhängige Dienste
Bibliotheken, die die Zeitschrift "Research Quarterly for Exercise and Sport" besitzen:
Link zur Zeitschriftendatenbank (ZDB)

Artikellieferdienst der deutschen Bibliotheken (subito):
Übernahme der Daten in das subito-Bestellformular

Tipps zum Auffinden elektronischer Volltexte im Video-Tutorial

Trefferlisten Einstellungen

Permalink als QR-Code

Permalink als QR-Code

Inhalt auf sozialen Plattformen teilen (nur vorhanden, wenn Javascript eingeschaltet ist)

Teile diese Seite: