Literaturnachweis - Detailanzeige
Autor/inn/en | Curran, Vernon; Fleet, Lisa; White, Susan; Bessell, Clare; Deshpandey, Akhil; Drover, Anne; Hayward, Mark; Valcour, James |
---|---|
Titel | A Randomized Controlled Study of Manikin Simulator Fidelity on Neonatal Resuscitation Program Learning Outcomes |
Quelle | In: Advances in Health Sciences Education, 20 (2015) 1, S.205-218 (14 Seiten)Infoseite zur Zeitschrift
PDF als Volltext |
Sprache | englisch |
Dokumenttyp | gedruckt; online; Zeitschriftenaufsatz |
ISSN | 1382-4996 |
DOI | 10.1007/s10459-014-9522-8 |
Schlagwörter | Simulation; Fidelity; Neonates; First Aid; Outcomes of Education; Pretests Posttests; Undergraduate Students; Medical Students; Teamwork; Student Behavior; Scores; Comparative Analysis; Satisfaction; Self Esteem; Medical Education |
Abstract | The neonatal resuscitation program (NRP) has been developed to educate physicians and other health care providers about newborn resuscitation and has been shown to improve neonatal resuscitation skills. Simulation-based training is recommended as an effective modality for instructing neonatal resuscitation and both low and high-fidelity manikin simulators are used. There is limited research that has compared the effect of low and high-fidelity manikin simulators for NRP learning outcomes, and more specifically on teamwork performance and confidence. The purpose of this study was to examine the effect of using low versus high-fidelity manikin simulators in NRP instruction. A randomized posttest-only control group study design was conducted. Third year undergraduate medical students participated in NRP instruction and were assigned to an experimental group (high-fidelity manikin simulator) or control group (low-fidelity manikin simulator). Integrated skills station (megacode) performance, participant satisfaction, confidence and teamwork behaviour scores were compared between the study groups. Participants in the high-fidelity manikin simulator instructional group reported significantly higher total scores in overall satisfaction (p = 0.001) and confidence (p = 0.001). There were no significant differences in teamwork behaviour scores, as observed by two independent raters, nor differences on mandatory integrated skills station performance items at the p < 0.05 level. Medical students' reported greater satisfaction and confidence with high-fidelity manikin simulators, but did not demonstrate overall significantly improved teamwork or integrated skills station performance. Low and high-fidelity manikin simulators facilitate similar levels of objectively measured NRP outcomes for integrated skills station and teamwork performance. (As Provided). |
Anmerkungen | Springer. 233 Spring Street, New York, NY 10013. Tel: 800-777-4643; Tel: 212-460-1500; Fax: 212-348-4505; e-mail: service-ny@springer.com; Web site: http://www.springerlink.com |
Erfasst von | ERIC (Education Resources Information Center), Washington, DC |
Update | 2020/1/01 |